cpqMeAlarmVariable
CPQTHRSH-MIB ·
.1.3.6.1.4.1.232.10.2.2.2.1.3
Object
column
mandatory
r/w
ObjectIdentifier
The object identifier of the particular variable to be
sampled. Only variables that resolve to an ASN.1 primitive
type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) may
be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value of
this object to identify only those objects that exist
in a particular MIB view. Because there is thus no
acceptable means of restricting the read access that
could be obtained through the alarm mechanism, the
agent must only grant write access to this object in
those views that have read access to all objects on
the agent.
During a set operation, if the supplied variable
name is not available in the selected MIB view, a
badValue error must be returned. If at any time
the variable name of an established cpqMeAlarmEntry is
no longer available in the selected MIB view, the
agent must change the status of this cpqMeAlarmEntry
to tempUnavailable(5).
This object may not be modified if the associated
cpqMeAlarmStatus object is equal to valid(1).
Context
- MIB
- CPQTHRSH-MIB
- OID
.1.3.6.1.4.1.232.10.2.2.2.1.3- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- cpqMeAlarmEntry
Syntax
ObjectIdentifier
Values & Constraints
No enumerated values or constraints recorded.