cpqSePCIeDiskWearStatus

CPQSTDEQ-MIB · .1.3.6.1.4.1.232.1.2.23.1.1.13

Object

column optional Enumeration
Wear Status of a PCIe Disk.
This shows the wear status of the solid state PCIe physical drive.
The following values are valid for the physical drive solid state
wear status:
Other (1)
  The instrument agent is unable to determine the physical drive's
  solid state disk wear status. This value would be used for non
  SSD drives or SSD drives that do not support wear reporting.
Ok (2)
  Indicates the solid state disk is not in any imminent danger
  of wear out.
              
Fifty Six Day Threshold Passed (3)
  Indicates that based upon the current workload, the solid state
  disk will reach the maximum usage limit for writes (wear out)
  within fifty-six days. You should modify your write workload or
  begin preparing to replace your SSD drive.
              
Five Percent Threshold Passed (4)
  Indicates that the solid state disk has passed the five percent
  threshold and is at or below five percent of reaching the maximum
  usage limit for writes (wear out). You should begin to prepare
  to replace your SSD drive.
              
Two Percent Threshold Passed (5)
  Indicates that the solid state disk has passed the two percent
  threshold and is at or below two percent of reaching the maximum
  usage limit for writes (wear out). You should begin to prepare
  to replace your SSD drive.
              
SSD Wear Out(6)
  Indicates that a solid state drive is approaching the maximum
  usage limit for writes (wear out) and should be replaced as soon
  as possible.

Context

MIB
CPQSTDEQ-MIB
OID
.1.3.6.1.4.1.232.1.2.23.1.1.13
Type
column
Access
readonly
Status
optional
Parent
cpqSePCIeDiskEntry
Table
cpqSePCIeDiskTable
Siblings
14

Syntax

Enumeration

Values & Constraints

Enumerated Values
1other
2ok
3fiftySixDayThreshold
4fivePercentThreshold
5twoPercentThreshold
6ssdWearOut