cpqSeIOCLEDState
CPQSTDEQ-MIB ·
.1.3.6.1.4.1.232.1.2.17.1.1.6
Object
column
optional
r/w
Integer32
This value represents the state of a IO Chassis LED.
This is a bit-mapped value defined as follows.
Bit 31..30 = 00, LED 3 is Off
= 01, LED 3 is On
= 10, LED 3 is Blinking
= 11, For LED 3 future use
Bit 29..27 = 000, LED 3 is Red
= 001, LED 3 is Yellow
= 010, LED 3 is Green
= 011, LED 3 is Blue
= 100, For LED 3 future use
= 101, For LED 3 future use
= 110, For LED 3 future use
= 111, For LED 3 future use
Bit 26..24 = 000, LED 3 indicates Power
= 001, LED 3 indicates Run
= 010, LED 3 indicates Attention
= 011, LED 3 indicates Fault
= 100, For LED 3 future use
= 101, For LED 3 future use
= 110, For LED 3 future use
= 111, For LED 3 future use
Bit 23..22 = 00, LED 2 is Off
= 01, LED 2 is On
= 10, LED 2 is Blinking
= 11, For LED 2 future use
Bit 21..19 = 000, LED 2 is Red
= 001, LED 2 is Yellow
= 010, LED 2 is Green
= 011, LED 2 is Blue
= 100, For LED 2 future use
= 101, For LED 2 future use
= 110, For LED 2 future use
= 111, For LED 2 future use
Bit 18..16 = 000, LED 2 indicates Power
= 001, LED 2 indicates Run
= 010, LED 2 indicates Attention
= 011, LED 2 indicates Fault
= 100, For LED 2 future use
= 101, For LED 2 future use
= 110, For LED 2 future use
= 111, For LED 2 future use
Bit 15..14 = 00, LED 1 is Off
= 01, LED 1 is On
= 10, LED 1 is Blinking
= 11, For LED 1 future use
Bit 13..11 = 000, LED 1 is Red
= 001, LED 1 is Yellow
= 010, LED 1 is Green
= 011, LED 1 is Blue
= 100, For LED 1 future use
= 101, For LED 1 future use
= 110, For LED 1 future use
= 111, For LED 1 future use
Bit 10..8 = 000, LED 1 indicates Power
= 001, LED 1 indicates Run
= 010, LED 1 indicates Attention
= 011, LED 1 indicates Fault
= 100, For LED 1 future use
= 101, For LED 1 future use
= 110, For LED 1 future use
= 111, For LED 1 future use
Bit 7..6 = 00, LED 0 is Off
= 01, LED 0 is On
= 10, LED 0 is Blinking
= 11, For LED 0 future use
Bit 5..3 = 000, LED 0 is Red
= 001, LED 0 is Yellow
= 010, LED 0 is Green
= 011, LED 0 is Blue
= 100, For LED 0 future use
= 101, For LED 0 future use
= 110, For LED 0 future use
= 111, For LED 0 future use
Bit 2..0 = 000, LED 0 indicates Power
= 001, LED 0 indicates Run
= 010, LED 0 indicates Attention
= 011, LED 0 indicates Fault
= 100, For LED 0 future use
= 101, For LED 0 future use
= 110, For LED 0 future use
= 111, For LED 0 future use
Context
- MIB
- CPQSTDEQ-MIB
- OID
.1.3.6.1.4.1.232.1.2.17.1.1.6- Type
- column
- Access
- readwrite
- Status
- optional
- Parent
- cpqSeIOCEntry
- Table
- cpqSeIOCTable
- Siblings
- 5
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqSeIOCUnitIndex optional This is a number that uniquely specifies the I/O chassis. | column | Integer32 | .1.3.6.1.4.1.232.1.2.17.1.1.1 |
| cpqSeIOCCabinetNumber optional This value represents the cabinet that the I/O chassis belongs to.
The default value is 255 if the cabinet number can not be obtained. | column | Integer32 | .1.3.6.1.4.1.232.1.2.17.1.1.2 |
| cpqSeIOCBayNumber optional This value indicates the bay in the cabinet where the I/O chassis resides. | column | Integer32 | .1.3.6.1.4.1.232.1.2.17.1.1.3 |
| cpqSeIOCIOCNumber optional This is the I/O chassis number that is unique across the bay. | column | Integer32 | .1.3.6.1.4.1.232.1.2.17.1.1.4 |
| cpqSeIOCPowerState optional This value indicates I/O chassis power state. | column | Enumeration | .1.3.6.1.4.1.232.1.2.17.1.1.5 |