cpqSeCellLEDState

CPQSTDEQ-MIB · .1.3.6.1.4.1.232.1.2.16.1.1.15

Object

column optional r/w Integer32
This value represents state of the cell LED.
This is a bit-mapped value defined as follows.
Bit 31..30 = 00, LED 3 is Off
           = 01, LED 3 is On
           = 10, LED 3 is Blinking
           = 11, For LED 3 future use
              
Bit 29..27 = 000, LED 3 is Red
           = 001, LED 3 is Yellow
           = 010, LED 3 is Green
           = 011, LED 3 is Blue
           = 100, For LED 3 future use
           = 101, For LED 3 future use
           = 110, For LED 3 future use
           = 111, For LED 3 future use
              
Bit 26..24 = 000, LED 3 indicates Power
           = 001, LED 3 indicates Run
           = 010, LED 3 indicates Attention
           = 011, LED 3 indicates Fault
           = 100, For LED 3 future use
           = 101, For LED 3 future use
           = 110, For LED 3 future use
           = 111, For LED 3 future use
              
Bit 23..22 = 00, LED 2 is Off
           = 01, LED 2 is On
           = 10, LED 2 is Blinking
           = 11, For LED 2 future use
              
Bit 21..19 = 000, LED 2 is Red
           = 001, LED 2 is Yellow
           = 010, LED 2 is Green
           = 011, LED 2 is Blue
           = 100, For LED 2 future use
           = 101, For LED 2 future use
           = 110, For LED 2 future use
           = 111, For LED 2 future use
              
Bit 18..16 = 000, LED 2 indicates Power
           = 001, LED 2 indicates Run
           = 010, LED 2 indicates Attention
           = 011, LED 2 indicates Fault
           = 100, For LED 2 future use
           = 101, For LED 2 future use
           = 110, For LED 2 future use
           = 111, For LED 2 future use
              
Bit 15..14 = 00, LED 1 is Off
           = 01, LED 1 is On
           = 10, LED 1 is Blinking
           = 11, For LED 1 future use
              
Bit 13..11 = 000, LED 1 is Red
           = 001, LED 1 is Yellow
           = 010, LED 1 is Green
           = 011, LED 1 is Blue
           = 100, For LED 1 future use
           = 101, For LED 1 future use
           = 110, For LED 1 future use
           = 111, For LED 1 future use
              
Bit 10..8  = 000, LED 1 indicates Power
           = 001, LED 1 indicates Run
           = 010, LED 1 indicates Attention
           = 011, LED 1 indicates Fault
           = 100, For LED 1 future use
           = 101, For LED 1 future use
           = 110, For LED 1 future use
           = 111, For LED 1 future use
              
Bit 7..6   = 00, LED 0 is Off
           = 01, LED 0 is On
           = 10, LED 0 is Blinking
           = 11, For LED 0 future use
              
Bit 5..3   = 000, LED 0 is Red
           = 001, LED 0 is Yellow
           = 010, LED 0 is Green
           = 011, LED 0 is Blue
           = 100, For LED 0 future use
           = 101, For LED 0 future use
           = 110, For LED 0 future use
           = 111, For LED 0 future use
              
Bit 2..0   = 000, LED 0 indicates Power
           = 001, LED 0 indicates Run
           = 010, LED 0 indicates Attention
           = 011, LED 0 indicates Fault
           = 100, For LED 0 future use
           = 101, For LED 0 future use
           = 110, For LED 0 future use
           = 111, For LED 0 future use

Context

MIB
CPQSTDEQ-MIB
OID
.1.3.6.1.4.1.232.1.2.16.1.1.15
Type
column
Access
readwrite
Status
optional
Parent
cpqSeCellEntry
Table
cpqSeCellTable
Siblings
22

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects