cpqSiSysBatteryFullCap
CPQSINFO-MIB ·
.1.3.6.1.4.1.232.2.2.10.2.1.14
Object
column mandatory
Integer32
This is the mWatt-Hours of the battery`s Full capacity on
the current charge.
If this attribute is not supported, 65535 is returned.
Context
- MIB
- CPQSINFO-MIB
- OID
.1.3.6.1.4.1.232.2.2.10.2.1.14- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqSiSysBatteryEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQSINFO-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSINFO-MIB::cpqSiSysBatteryFullCap'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CPQSINFO-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSINFO-MIB::cpqSiSysBatteryFullCap.<cpqSiSysBatteryIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQSINFO-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQSINFO-MIB::cpqSiSysBatteryFullCap'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-65535