cpqScsiPhyDrvStatus
CPQSCSI-MIB ·
.1.3.6.1.4.1.232.5.2.4.1.1.9
Object
column mandatory
Enumeration
SCSI Physical Drive Status.
The physical drive can be in one of the following states:
other(1)
The drive is in a state other than one of those listed
below.
ok(2)
Indicates that the physical drive is in normal operation mode.
No user action is necessary.
failed(3)
Indicates that the physical drive has failed and can no longer
return data. When convenient, you should bring down the server
and run diagnostics to help identify the problem.
The drive may need to be replaced.
notConfigured(4)
Indicates that the physical drive is not configured. You
need to insure all of the drive`s switches are properly set
and that the configuration utility has been run.
badCable(5)
Indicates that a physical drive is not responding.
You should check the cables connected to it. You can bring
down the server and run diagnostics to help identify
the problem.
missingWasOk(6)
Indicates that a physical drive had a status of OK and is no
longer present. The drive has been removed.
missingWasFailed(7)
Indicates that a physical drive had a status of FAILED and is
no longer present. The drive has been removed.
predictiveFailure(8)
Indicates that the physical drive has exceeded a threshold
value for one of it`s predictive indicators. When convenient,
you should bring down the server and run diagnostics to
help identify the problem. The drive may need to be replaced.
missingWasPredictiveFailure(9)
Indicates that a physical drive had a status of PREDICTIVE
FAILURE and is no longer present. The drive has been removed.
offline(10)
Indicates that the physical drive is offline and can no longer
return data. No further status is available.
missingWasOffline(11)
Indicates that a physical drive had a status of OFFLINE
and is no longer present. The drive has been removed.
hardError(12)
Indicates that a hard error occurred for this physical drive.
Context
- MIB
- CPQSCSI-MIB
- OID
.1.3.6.1.4.1.232.5.2.4.1.1.9- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqScsiPhyDrvEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSCSI-MIB::cpqScsiPhyDrvStatus'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSCSI-MIB::cpqScsiPhyDrvStatus.<cpqScsiPhyDrvCntlrIndex>.<cpqScsiPhyDrvBusIndex>.<cpqScsiPhyDrvIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQSCSI-MIB::cpqScsiPhyDrvStatus'
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | ok |
3 | failed |
4 | notConfigured |
5 | badCable |
6 | missingWasOk |
7 | missingWasFailed |
8 | predictiveFailure |
9 | missingWasPredictiveFailure |
10 | offline |
11 | missingWasOffline |
12 | hardError |