cpqScsiPhyDrvStatus

CPQSCSI-MIB · .1.3.6.1.4.1.232.5.2.4.1.1.9

Object

column mandatory Enumeration
SCSI Physical Drive Status.
              
The physical drive can be in one of the following states:
              
other(1)
  The drive is in a state other than one of those listed
  below.
              
ok(2)
  Indicates that the physical drive is in normal operation mode.
  No user action is necessary.
              
failed(3)
  Indicates that the physical drive has failed and can no longer
  return data.  When convenient, you should bring down the server
  and run diagnostics to help identify the problem.
  The drive may need to be replaced.
              
notConfigured(4)
  Indicates that the physical drive is not configured.  You
  need to insure all of the drive`s switches are properly set
  and that the configuration utility has been run.
              
badCable(5)
  Indicates that a physical drive is not responding.
  You should check the cables connected to it.  You can bring
  down the server and run diagnostics to help identify
  the problem.
              
missingWasOk(6)
  Indicates that a physical drive had a status of OK and is no
  longer present.  The drive has been removed.
              
missingWasFailed(7)
  Indicates that a physical drive had a status of FAILED and is
  no longer present.  The drive has been removed.
              
predictiveFailure(8)
  Indicates that the physical drive has exceeded a threshold
  value for one of it`s predictive indicators. When convenient,
  you should bring down the server and run diagnostics to
  help identify the problem. The drive may need to be replaced.
              
missingWasPredictiveFailure(9)
  Indicates that a physical drive had a status of PREDICTIVE
  FAILURE and is no longer present.  The drive has been removed.
              
offline(10)
  Indicates that the physical drive is offline and can no longer
  return data.  No further status is available.
              
missingWasOffline(11)
  Indicates that a physical drive had a status of OFFLINE
  and is no longer present.  The drive has been removed.
              
hardError(12)
  Indicates that a hard error occurred for this physical drive.

Context

MIB
CPQSCSI-MIB
OID
.1.3.6.1.4.1.232.5.2.4.1.1.9
Type
column
Access
readonly
Status
mandatory
Parent
cpqScsiPhyDrvEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSCSI-MIB::cpqScsiPhyDrvStatus'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSCSI-MIB::cpqScsiPhyDrvStatus.<cpqScsiPhyDrvCntlrIndex>.<cpqScsiPhyDrvBusIndex>.<cpqScsiPhyDrvIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQSCSI-MIB::cpqScsiPhyDrvStatus'

Syntax

Enumeration

Values & Constraints

Enumerated Values
1other
2ok
3failed
4notConfigured
5badCable
6missingWasOk
7missingWasFailed
8predictiveFailure
9missingWasPredictiveFailure
10offline
11missingWasOffline
12hardError