cpqSasPhyDrvStatus
CPQSCSI-MIB ·
.1.3.6.1.4.1.232.5.5.2.1.1.5
Object
column mandatory
Enumeration
SAS Physical Drive Status.
The physical drive can be in one of the following states:
other(1)
The drive is in a state other than one of those listed
below.
ok(2)
Indicates that the physical drive is in normal operation mode.
No user action is necessary.
predictiveFailure(3)
Indicates that the physical drive has exceeded a threshold
value for one of it`s predictive indicators.
offline(4)
Indicates that the physical drive is offline and can no longer
return data. No further status is available.
failed(5)
Indicates that the physical drive has failed and can no longer
return data.
missingWasOk(6)
Indicates that a physical drive had a status of ok(2) and is
no longer present. The drive has been removed.
missingWasPredictiveFailure(7)
Indicates that a physical drive had a status of
predictiveFailure(3) and is no longer present. The drive has
been removed.
missingWasOffline(8)
Indicates that a physical drive had a status of offline(4) and
is no longer present. The drive has been removed.
missingWasFailed(9)
Indicates that a physical drive had a status of failed(5) and
is no longer present. The drive has been removed.
ssdWearOut(10)
Indicates that the solid state drive has a S.M.A.R.T wear
error and is approaching the maximum usage limit for writes
(wear out). The solid state drive should be replaced as soon as
possible.
missingWasSSDWearOut(11)
Indicates that a physical drive had a status of ssdWearout(10)
and is no longer present. The drive has been removed.
notAuthenticated(12)
Indicates the physical drive could not be authenticated as a genuine
HP hard drive. The host bus adapter will no longer control the drive
LEDs. Please replace the hard drive with a genuine HP hard drive.
missingNotAuthenticated(13)
Indicates that a physical drive had a status of notAuthenticated(12)
and is no longer present. The drive has been removed.
Context
- MIB
- CPQSCSI-MIB
- OID
.1.3.6.1.4.1.232.5.5.2.1.1.5- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqSasPhyDrvEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSCSI-MIB::cpqSasPhyDrvStatus'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQSCSI-MIB::cpqSasPhyDrvStatus.<cpqSasPhyDrvHbaIndex>.<cpqSasPhyDrvIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQSCSI-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQSCSI-MIB::cpqSasPhyDrvStatus'
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | ok |
3 | predictiveFailure |
4 | offline |
5 | failed |
6 | missingWasOk |
7 | missingWasPredictiveFailure |
8 | missingWasOffline |
9 | missingWasFailed |
10 | ssdWearOut |
11 | missingWasSSDWearOut |
12 | notAuthenticated |
13 | missingWasNotAuthenticated |