sCellEventTrap-06-3e
CPQHSV-MIB ·
.1.3.6.1.4.1.232.0.13601598
Object
notification
Severity: Critical -- failure or failure imminent. The HSV210 controller has detected an enclosure on the Fibre Channel but is unable to communicate with the Drive Enclosure Environmental Monitoring Unit on the enclosure address bus or the Drive Enclosure Environmental Monitoring Unit is reporting an invalid enclosure number.
Context
- MIB
- CPQHSV-MIB
- OID
.1.3.6.1.4.1.232.0.13601598- Type
- notification
- Status
- current
- Parent
- compaq
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'CPQHSV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV-MIB::sCellEventTrap-06-3e'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQHSV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV-MIB::sCellEventTrap-06-3e'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.