cpqFcaPhyDrvOtherTimeouts

CPQFCA-MIB · .1.3.6.1.4.1.232.16.2.5.1.1.25

Object

column mandatory RFC1155-SMICounter
Other Timeouts.
              
The number of times that a physical drive did not respond with an
interrupt within a controller-defined period of time after a
command had been issued during the reference time (phyDrvRefTime).
This does not include DRQ timeouts.
              
If you suspect a problem, complete the following steps for the
monitored system:
              
1.  Check the cables connecting the drive to ensure that they
    are intact.
              
2.  If the cables are properly connected, run diagnostics to
    verify that a problem exists.
              
If the value cannot be determined, 4,294,967,295 is
returned.

Context

MIB
CPQFCA-MIB
OID
.1.3.6.1.4.1.232.16.2.5.1.1.25
Type
column
Access
readonly
Status
mandatory
Parent
cpqFcaPhyDrvEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQFCA-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQFCA-MIB::cpqFcaPhyDrvOtherTimeouts'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CPQFCA-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQFCA-MIB::cpqFcaPhyDrvOtherTimeouts.<cpqFcaPhyDrvBoxIndex>.<cpqFcaPhyDrvIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQFCA-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQFCA-MIB::cpqFcaPhyDrvOtherTimeouts'

Syntax

Source
RFC1155-SMICounter
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295