cpqFcaAccelBatteryStatus
CPQFCA-MIB ·
.1.3.6.1.4.1.232.16.2.2.2.1.6
Object
column
mandatory
Enumeration
Array Accelerator Board Battery Status.
This monitors the status of each battery pack on the board. The
batteries can only recharge when the system has power applied.
The following values are valid:
Other (1)
Indicates that the instrument agent does not recognize
battery status. You may need to update your software.
Ok (2)
Indicates that a particular battery pack is fully charged.
Charging (3)
The battery power is less than 75%. The array controller
is attempting to recharge the battery. A battery can take
as long as 36 hours to fully recharge. After 36 hours,
if the battery has not recharged, it is considered failed.
Failed (4)
The battery pack is below the sufficient voltage level and
has not recharged in 36 hours. Your Array Accelerator board
needs to be serviced.
Degraded (5)
The battery is still operating, however, one of the batteries
in the pack has failed to recharge properly. Your Array
Accelerator board should be serviced as soon as possible.
NotPresent (6)
There are no batteries associated with this controller.
Context
- MIB
- CPQFCA-MIB
- OID
.1.3.6.1.4.1.232.16.2.2.2.1.6- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqFcaAccelEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | ok |
3 | recharging |
4 | failed |
5 | degraded |
6 | notPresent |