smIOCompatibility
CME-MIB ·
.1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18
Object
column
mandatory
OctetString
The compatibility status for the I/O module.
The possible values and their meanings are as follows:
Unknown: This indicates a communication error for the I/O module.
OK: This is the normal (good) case where there are no compatibility
issues between the I/O module and the modules it is internally wired to.
No Fabric: This means the other end is not populated on any of the
modules this I/O module is internally wired to (e.g. this is an
Infiniband switch but none of the blades it is internally wired to
has an expansion card attached in the corresponding expansion slot).
Attention: Indicates one of the following cases:
One or more of the modules this I/O module is internally wired to is in communication error
The I/O module is powered off and at least one module it is internally wired to is powered on
Mismatch: Indicates one of the following cases:
Fabric types are incompatible
An unknown I/O module type
An unknown fabric type on a module the I/O module is internally wired to.
Context
- MIB
- CME-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- smControlEntry
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.