prtoutputremainingcapacity
CLJ8550-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5
Object
The remaining capacity of the possible output sub-unit
capacity in output sub-unit capacity units (PrtCapacityUnitTC)
of this output sub-unit. If this output sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be modified by management requests;
otherwise, the value may be written (by
a Remote Control Panel or a Management
Application). The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means
unknown. The value (-3) means that the printer knows that
there remains capacity for at least one unit.
Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
Additional information:
Replaces PML NOT-READY-OUTBIN-FULL and
STATUS-OUTBIN-FULL.
The values reported for output sub-unit 1 (face-down, top bin)
will be either (-3) if it is not full or (0) if it is full.
Output sub-unit 2 (face-up, left side bin) does not have any
sensing, so it will always report unknown (-2).
The first output sub-unit (3) of the HCO reports either (62)
if it is not full, (125) when empty, or (0) if it is full.
In mailbox mode, the HCO sub-units (4-11) will report (250)
when empty, (125) when there's room for <250 sheets and (0)
when full.
In stacker and job separator modes all bins are treated as a
single output bin so sub-unit 4 will report (2000) when all
bins are empty. A value of (0) is reported when the topmost
bin is full (stacker mode) or when a bins is full
(separator mode).
When the stacker or separator has started filling, the value
reported is based on the number of bins that are empty,
partially filled and full.
A percentage is calculated based on the status of each bin.
Each full bin counts 1, each not empty/not full bin counts
0.5 and each empty bin counts 0. The result is mapped to an
estimate of the remaining capacity as follows (percent full
is included here for completeness, since that is how the
HCO reports it to the printer):
0.0 2000 (100%)
0.5 1900 ( 90%)
1.0 1800 ( 85%)
1.5 1700 ( 80%)
2.0 1500 ( 75%)
2.5 1400 ( 65%)
3.0 1300 ( 60%)
3.5 1200 ( 55%)
4.0 1000 ( 50%)
4.5 900 ( 40%)
5.0 800 ( 35%)
5.5 700 ( 30%)
6.0 500 ( 25%)
6.5 400 ( 15%)
7.0 300 ( 10%)
7.5 200 ( 5%)
8.0 0 ( 0%)
Note: Due to HCO mechanism limitations, the value reported may
not always be accurate (the bin status is detected only when
the media delivery head is moved to or past a physical bin).
Also, for stacker mode a bin is considered full as long as any
bin above it is not empty.
Default values assume all sub-units are empty and the HCO is
in mailbox mode.
Context
- MIB
- CLJ8550-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5- Type
- scalar
- Access
- readonly
- Status
- optional
- Parent
- prtOutputEntry
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CLJ8550-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CLJ8550-MIB::prtoutputremainingcapacity.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CLJ8550-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CLJ8550-MIB::prtoutputremainingcapacity'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647