prtinputcurrentlevel

CLJ8550-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.10

Object

scalar optional Integer32
The current capacity of the input sub-unit in input
sub-unit capacity units (PrtCapacityUnitTC). If this input
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by
management requests; otherwise, the value may
be written (by a Remote Contol Panel or a
Management Application).  The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means unknown.
The value (-3) means that the printer knows that at least one
unit remains.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
        Additional information:
        For trays 1, Color LaserJet8550 can only detect empty/not 
        empty trays. It returns -3 for not empty and 0 for 
        empty.  
        			For trays 2 (8550 N and up) and 3, Color LaserJet8550 can detect 
        			approximately the amount of media. The value returned 
        			is based on the amount detected as follows:  
        			0 - empty   
        			1 - 1-110 sheets  
        			50 - 50-260 sheets  
        			200 - 200-490 sheets  
        			430 - 430 sheets or more  
        			For tray 4, Color LaserJet8550 can detect approximately the amount 
        			of media. The value returned is based on the amount 
        			detected as follows:  
        			0 - empty   
        			1 - 1 sheet to 25% of capacity  
        			500 - 26% to 50% of capacity  
        			1000 - 51% to 75% of capacity  
        			1500 - 76% to 100% of capacity  
        			If the tray drawer is open, a value of -2 (unknown) 
        			will  be returned.

Context

MIB
CLJ8550-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.10
Type
scalar
Access
readonly
Status
optional
Parent
prtInputEntry

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CLJ8550-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CLJ8550-MIB::prtinputcurrentlevel.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CLJ8550-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CLJ8550-MIB::prtinputcurrentlevel'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647