job-input-auto-continue-timeout

CLJ8550-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.35

Object

scalar optional r/w Integer32
The number of seconds the device waits after a job
related continuable error occurs before automatically
continuing.  An example job related continuable error is
the job requesting a media size that is not available.
After the timeout expires, the device will continue
processing the job as if a continue event occurred, such
as the front panel continue key being pressed.  If the
value is -1, the device does not automatically continue
after a job related continuable error occurs.  If the
value is 0, the device immediately continues.  If the
value is greater than 0, the value represents the
timeout value in seconds.
Additional information:
This object is used only for media requests 
			(size and/or name).  
			Color LaserJet8550 supports any value in the range of -1 to 3600. 
			Setting to a value outside of that range causes  
the printer to substitute a value (listed 
below) and to return <noError> 
status.  
The values are as follow:  
<-1 snaps to -1  
>3600 snaps to 3600  (60 minutes)  
			The action that occurs when this timeout expires is 
			explained by JOB-INPUT-AUTO-CONTINUE-MODE. It is not 
			the same as the CONTINUE object being set to 
			eInitiateAction or the Go key being pressed on
			the control panel. See 
			the CONTINUE object description for information on the 
			actions that occur for those conditions.

Context

MIB
CLJ8550-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.35
Type
scalar
Access
readwrite
Status
optional
Parent
status-system

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CLJ8550-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CLJ8550-MIB::job-input-auto-continue-timeout.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CLJ8550-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CLJ8550-MIB::job-input-auto-continue-timeout'

Syntax

Integer32

Values & Constraints

Object Constraints
range: -1-3600