mtaDevPwrSupplyConfigRunTime

CLAB-UPS-MIB · .1.3.6.1.4.1.4491.4.1.1.1.2

Object

scalar r/w minutesSNMPv2-SMIInteger32
This attribute provides the current programmed battery backup 
minimum run time value. The minimum battery backup run time 
may also from this value. By programming the run-time to a 
lower value, the total service life of the battery is extended
by decreasing the battery's recharge threshold causing it to  
recharge less often and to maintain a lower average charge state.
Increasing the run-time value in turn decreases the total service
life of the battery by causing it to recharge more often and to 
maintain a higher average charge state. Setting this value greater
than MtaDevPwrSupplyAvailableMinutes will not provide a run-time 
greater than the value in MtaDevPwrSupplyAvailableMinutes.