mtaDevPwrSupplyConfigRunTime
CLAB-UPS-MIB ·
.1.3.6.1.4.1.4491.4.1.1.1.2
Object
scalar
r/w
minutes Integer32
This attribute provides the current programmed battery backup minimum run time value. The minimum battery backup run time may also from this value. By programming the run-time to a lower value, the total service life of the battery is extended by decreasing the battery's recharge threshold causing it to recharge less often and to maintain a lower average charge state. Increasing the run-time value in turn decreases the total service life of the battery by causing it to recharge more often and to maintain a higher average charge state. Setting this value greater than MtaDevPwrSupplyAvailableMinutes will not provide a run-time greater than the value in MtaDevPwrSupplyAvailableMinutes.
Context
- MIB
- CLAB-UPS-MIB
- OID
.1.3.6.1.4.1.4491.4.1.1.1.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- minutes
- Parent
- clabSupplemtalGroup
Syntax
minutes Integer32
Values & Constraints
No enumerated values or constraints recorded.