vismContinuityCo1Timer
CISCO-VISM-MODULE-MIB ·
.1.3.6.1.4.1.351.110.3.17.4.30
Object
scalar
r/w
Integer32
A 2010Hz tone is applied, if the co1(Continuity Tone 1) is specify as a signal the range is 2010Hz +/- 8Hz and if it is specify as an event the range is 2010Hz +/- 30Hz. The continuity tone is applied for the specified duration of time in seconds.
Context
- MIB
- CISCO-VISM-MODULE-MIB
- OID
.1.3.6.1.4.1.351.110.3.17.4.30- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- vismSystemGrp
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-60