vismBearerContinuityTest

CISCO-VISM-MODULE-MIB · .1.3.6.1.4.1.351.110.3.17.4.26

Object

scalar r/w SNMPv2-TCTruthValue
This attribute defines whether the bearer continuity
test for a connection will be performed at the time of
call setup or not.
          
When the vismBearerContinuityTest is enabled, the 
terminating media Gateway initiates a NSE/Type 3 packet 
towards the originating gateway and starts a timer
defined by vismBearerContinuityTimer. 
          
The originating gateway, on receipt of co3, responds by 
sending a co4 to the terminating end.
          
If the terminating gateway doesn't receive co4 NSE/Type 3
packet with in the time defined by co4 timer, it
initiates a GW-initiated DLCX to the call agent which
in turn deletes the connection.
           
The value in this object will be utilized when the call
agent does not specify this.

Context

MIB
CISCO-VISM-MODULE-MIB
OID
.1.3.6.1.4.1.351.110.3.17.4.26
Type
scalar
Access
readwrite
Status
current
Parent
vismSystemGrp

Syntax

SNMPv2-TCTruthValue

Values & Constraints

No enumerated values or constraints recorded.