vismChanUserMaxScrIngress
CISCO-VISM-CONN-MIB ·
.1.3.6.1.4.1.351.110.5.5.3.1.1.1.52
Object
column
r/w
cells-per-second Unsigned32
This object defines a user configured SCR (Sustained Cell Rate) for the PVC. SCR is used for vbr connection types only. Although, based on the value of SCR, any kind of traffic shaping is not done on the VISM card, this value is useful for setting up the parameters for the end-to-end PVC. This value is expressed in units of cells per second. This object defines the SCR value for the ingress direction of the PVC. For a VOIP bearer PVC the max value is 80000. For a VOIP control PVC the max value is 20000 increased as we will allow 248 endpoints. For Aal2 the values remain the same (50000/60000). If the user provides a value that is greater than vismConnPCR then the SET request will be rejected. For vbr connections the allowed range of values of SCR is from 15 - PCR.
Context
- MIB
- CISCO-VISM-CONN-MIB
- OID
.1.3.6.1.4.1.351.110.5.5.3.1.1.1.52- Type
- column
- Access
- readwrite
- Status
- current
- Units
- cells-per-second
- Parent
- vismChanCnfGrpEntry
Syntax
cells-per-second Unsigned32
Values & Constraints
Object Constraints
range: 1-100000