cPtpClockTODEnabled
CISCO-PTP-MIB ·
.1.3.6.1.4.1.9.9.760.1.1.3.1.6
Object
column
SNMPv2-TCTruthValue
This object specifies whether the node is enabled for TOD.
Context
- MIB
- CISCO-PTP-MIB
- OID
.1.3.6.1.4.1.9.9.760.1.1.3.1.6- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cPtpClockNodeEntry
- Table
- cPtpClockNodeTable
- Siblings
- 12
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cPtpClockDomainIndex This object specifies the domain number used to create logical
group of PTP devices. | column | ClockDomainType | .1.3.6.1.4.1.9.9.760.1.1.3.1.1 |
| cPtpClockOutput1ppsOffsetNegative This object specifies whether the added (fixed) offset to the
1pps output is negative or not. When object returns TRUE the
offset is negative and when object returns FALSE the of… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.1.3.1.10 |
| cPtpClockInput1ppsInterface This object specifies the 1pps interface used for PTP input
clocking. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9.9.760.1.1.3.1.11 |
| cPtpClockOutput1ppsInterface This object specifies the 1pps interface used for PTP output
clocking. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9.9.760.1.1.3.1.12 |
| cPtpClockTODInterface This object specifies the interface used for PTP TOD. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9.9.760.1.1.3.1.13 |
| cPtpClockTypeIndex This object specifies the clock type as defined in the
Textual convention description. | column | ClockType | .1.3.6.1.4.1.9.9.760.1.1.3.1.2 |
| cPtpClockInstanceIndex This object specifies the instance of the Clock for this clock
type for the given domain. | column | Unsigned32 | .1.3.6.1.4.1.9.9.760.1.1.3.1.3 |
| cPtpClockInput1ppsEnabled This object specifies whether the node is enabled for PTP input
clocking using the 1pps interface. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.1.3.1.4 |
| cPtpClockInputFrequencyEnabled This object specifies whether enabled for Frequency input using
the 1.544 Mhz, 2.048 Mhz, or 10Mhz timing interface. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.1.3.1.5 |
| cPtpClockOutput1ppsEnabled This object specifies whether the node is enabled for PTP input
clocking using the 1pps interface. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.1.3.1.7 |
| cPtpClockOutput1ppsOffsetEnabled This object specifies whether an offset is configured in order
to compensate for a known phase error such as network
asymmetry. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.1.3.1.8 |
| cPtpClockOutput1ppsOffsetValue This object specifies the fixed offset value configured to be
added for the 1pps output. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.9.760.1.1.3.1.9 |