cPtpClockPortNumOfAssociatedPorts
CISCO-PTP-MIB ·
.1.3.6.1.4.1.9.9.760.1.2.7.1.10
Object
column
SNMPv2-SMIGauge32
This object specifies - For a master port - the number of PTP slave sessions (peers) associated with this PTP port. For a slave port - the number of masters available to this slave port (might or might not be peered).
Context
- MIB
- CISCO-PTP-MIB
- OID
.1.3.6.1.4.1.9.9.760.1.2.7.1.10- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cPtpClockPortEntry
- Table
- cPtpClockPortTable
- Siblings
- 11
Syntax
SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cPtpClockPortDomainIndex This object specifies the domain number used to create logical
group of PTP devices. | column | ClockDomainType | .1.3.6.1.4.1.9.9.760.1.2.7.1.1 |
| cPtpClockPortBlockGMC This object specifies that the ptp port is configured with ptp
gmc-block or not. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.2.7.1.11 |
| cPtpClockRogueMasterDetect This object specifies that port receives the PTP packets from
other network, which the device is not interested to sync with. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.2.7.1.12 |
| cPtpClockPortClockTypeIndex This object specifies the clock type as defined in the
Textual convention description. | column | ClockType | .1.3.6.1.4.1.9.9.760.1.2.7.1.2 |
| cPtpClockPortClockInstanceIndex This object specifies the instance of the clock for this clock
type in the given domain. | column | Unsigned32 | .1.3.6.1.4.1.9.9.760.1.2.7.1.3 |
| cPtpClockPortTablePortNumberIndex This object specifies the PTP Portnumber for this port. | column | Unsigned32 | .1.3.6.1.4.1.9.9.760.1.2.7.1.4 |
| cPtpClockPortName This object specifies the PTP clock port name configured on the
router. | column | OctetString | .1.3.6.1.4.1.9.9.760.1.2.7.1.5 |
| cPtpClockPortRole This object describes the current role (slave/master) of the
port. | column | ClockRoleType | .1.3.6.1.4.1.9.9.760.1.2.7.1.6 |
| cPtpClockPortSyncOneStep This object specifies that one-step clock operation between
the PTP master and slave device is enabled. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.760.1.2.7.1.7 |
| cPtpClockPortCurrentPeerAddressType This object specifies the current peer's network address used
for PTP communication. Based on the scenario and the setup
involved, the values might look like these -
Scenario … | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.9.9.760.1.2.7.1.8 |
| cPtpClockPortCurrentPeerAddress This object specifies the current peer's network address used
for PTP communication. Based on the scenario and the setup
involved, the values might look like these -
Scenario … | column | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.9.9.760.1.2.7.1.9 |