clMeshNodeBatteryOutputPower
CISCO-LWAPP-MESH-BATTERY-MIB ·
.1.3.6.1.4.1.9.9.620.1.1.1.1.10
Object
This object represents the output power of the battery.
Context
- MIB
- CISCO-LWAPP-MESH-BATTERY-MIB
- OID
.1.3.6.1.4.1.9.9.620.1.1.1.1.10- Type
- column
- Access
- readonly
- Status
- current
- Units
- milliWatts
- Parent
- clMeshNodeBatteryEntry
- Table
- clMeshNodeBatteryTable
- Siblings
- 13
Syntax
milliWatts SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| clMeshNodeBatteryModelName This object represents the model name of the battery. | column | OctetString | .1.3.6.1.4.1.9.9.620.1.1.1.1.1 |
| clMeshNodeBatteryInternalVoltage This object represents the internal voltage of
the battery. | column | milliVolts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.11 |
| clMeshNodeBatteryTemperature This object represents the temperature of the battery
in Celsius. | column | degree Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.12 |
| clMeshNodeBatteryCurrent deprecated This object represents the current of
the battery. Superceded by clMeshNodeBatteryCurrentValue. | column | milliAmps SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.13 |
| clMeshNodeBatteryCurrentValue This object represents the current of
the battery. | column | milliAmps SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.14 |
| clMeshNodeBatteryStatus This object represents the status of the battery.
unknown - Battery status is unknown.
normal - Battery is operating normally and is in
standby mode ready to … | column | Enumeration | .1.3.6.1.4.1.9.9.620.1.1.1.1.2 |
| clMeshNodeBatteryChargingState deprecated This object represents the charging status of
the battery.
unknown - Charging state is unknown,
disabled - Charging is disabled,
charging … | column | Enumeration | .1.3.6.1.4.1.9.9.620.1.1.1.1.3 |
| clMeshNodeBatteryChargingLevel This object represents the charging level of
the battery. | column | % SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.4 |
| clMeshNodeBatteryRemainingCapacity deprecated This object represents the remaining time of
the battery capacity. | column | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.5 |
| clMeshNodeBatterySwVersion This object represents the SW version of
the battery. | column | OctetString | .1.3.6.1.4.1.9.9.620.1.1.1.1.6 |
| clMeshNodeBatterySerialNumber This object represents the serial number of
the battery. | column | OctetString | .1.3.6.1.4.1.9.9.620.1.1.1.1.7 |
| clMeshNodeBatteryInputVoltage This object represents the AC voltage across the input
terminals the battery. | column | milliVolts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.8 |
| clMeshNodeBatteryOutputVoltage This object represents the voltage across the output (load)
terminals of the battery. | column | milliVolts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.9.620.1.1.1.1.9 |