cfprSwEthEstcEpPeerChassisId
CISCO-FIREPOWER-SW-MIB ·
.1.3.6.1.4.1.9.9.826.1.75.11.1.22
Object
column
SNMPv2-SMIGauge32
Cisco Firepower sw:EthEstcEp:peerChassisId managed object property
Context
- MIB
- CISCO-FIREPOWER-SW-MIB
- OID
.1.3.6.1.4.1.9.9.826.1.75.11.1.22- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cfprSwEthEstcEpEntry
- Table
- cfprSwEthEstcEpTable
- Siblings
- 35
Syntax
SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprSwEthEstcEpInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.75.11.1.1 |
| cfprSwEthEstcEpCdp Cisco Firepower sw:EthEstcEp:cdp managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNwctrlAdminState | .1.3.6.1.4.1.9.9.826.1.75.11.1.10 |
| cfprSwEthEstcEpChassisId Cisco Firepower sw:EthEstcEp:chassisId managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.11 |
| cfprSwEthEstcEpCosValue Cisco Firepower sw:EthEstcEp:cosValue managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.12 |
| cfprSwEthEstcEpEpDn Cisco Firepower sw:EthEstcEp:epDn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.75.11.1.13 |
| cfprSwEthEstcEpForgeMac Cisco Firepower sw:EthEstcEp:forgeMac managed object property | column | CISCO-FIREPOWER-TC-MIBCfprDpsecForgedTransmit | .1.3.6.1.4.1.9.9.826.1.75.11.1.14 |
| cfprSwEthEstcEpIfRole Cisco Firepower sw:EthEstcEp:ifRole managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkPortRole | .1.3.6.1.4.1.9.9.826.1.75.11.1.15 |
| cfprSwEthEstcEpIfType Cisco Firepower sw:EthEstcEp:ifType managed object property | column | CISCO-FIREPOWER-TC-MIBCfprSwPIoEpIfType | .1.3.6.1.4.1.9.9.826.1.75.11.1.16 |
| cfprSwEthEstcEpLc Cisco Firepower sw:EthEstcEp:lc managed object property | column | CISCO-FIREPOWER-TC-MIBCfprSwPIoEpLc | .1.3.6.1.4.1.9.9.826.1.75.11.1.17 |
| cfprSwEthEstcEpLocale Cisco Firepower sw:EthEstcEp:locale managed object property | column | CISCO-FIREPOWER-TC-MIBCfprSwEstcEpLocale | .1.3.6.1.4.1.9.9.826.1.75.11.1.18 |
| cfprSwEthEstcEpName Cisco Firepower sw:EthEstcEp:name managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.75.11.1.19 |
| cfprSwEthEstcEpDn Cisco Firepower sw:EthEstcEp:dn managed object property | column | CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.75.11.1.2 |
| cfprSwEthEstcEpPcId Cisco Firepower sw:EthEstcEp:pcId managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.20 |
| cfprSwEthEstcEpPeerAggrPortId Cisco Firepower sw:EthEstcEp:peerAggrPortId managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.21 |
| cfprSwEthEstcEpPeerDn Cisco Firepower sw:EthEstcEp:peerDn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.75.11.1.23 |
| cfprSwEthEstcEpPeerPortId Cisco Firepower sw:EthEstcEp:peerPortId managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.24 |
| cfprSwEthEstcEpPeerSlotId Cisco Firepower sw:EthEstcEp:peerSlotId managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.25 |
| cfprSwEthEstcEpPinGroupName Cisco Firepower sw:EthEstcEp:pinGroupName managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.75.11.1.26 |
| cfprSwEthEstcEpPortId Cisco Firepower sw:EthEstcEp:portId managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.27 |
| cfprSwEthEstcEpPortMode Cisco Firepower sw:EthEstcEp:portMode managed object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricEthEstcPortMode | .1.3.6.1.4.1.9.9.826.1.75.11.1.28 |
| cfprSwEthEstcEpPriorityFlowCtrl Cisco Firepower sw:EthEstcEp:priorityFlowCtrl
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprFlowctrlPriorityPause | .1.3.6.1.4.1.9.9.826.1.75.11.1.29 |
| cfprSwEthEstcEpRn Cisco Firepower sw:EthEstcEp:rn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.75.11.1.3 |
| cfprSwEthEstcEpRecvFlowCtrl Cisco Firepower sw:EthEstcEp:recvFlowCtrl managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFlowctrlFlowControlRx | .1.3.6.1.4.1.9.9.826.1.75.11.1.30 |
| cfprSwEthEstcEpSendFlowCtrl Cisco Firepower sw:EthEstcEp:sendFlowCtrl managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFlowctrlFlowControlTx | .1.3.6.1.4.1.9.9.826.1.75.11.1.31 |
| cfprSwEthEstcEpSlotId Cisco Firepower sw:EthEstcEp:slotId managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.32 |
| cfprSwEthEstcEpSwitchId Cisco Firepower sw:EthEstcEp:switchId managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId | .1.3.6.1.4.1.9.9.826.1.75.11.1.33 |
| cfprSwEthEstcEpTransport Cisco Firepower sw:EthEstcEp:transport managed object property | column | CISCO-FIREPOWER-TC-MIBCfprSwEthEstcEpTransport | .1.3.6.1.4.1.9.9.826.1.75.11.1.34 |
| cfprSwEthEstcEpType Cisco Firepower sw:EthEstcEp:type managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkConnectionType | .1.3.6.1.4.1.9.9.826.1.75.11.1.35 |
| cfprSwEthEstcEpUplinkFailAction Cisco Firepower sw:EthEstcEp:uplinkFailAction
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNwctrlLinkFailAction | .1.3.6.1.4.1.9.9.826.1.75.11.1.36 |
| cfprSwEthEstcEpAdminSpeed Cisco Firepower sw:EthEstcEp:adminSpeed managed object property | column | CISCO-FIREPOWER-TC-MIBCfprPortEthSpeed | .1.3.6.1.4.1.9.9.826.1.75.11.1.4 |
| cfprSwEthEstcEpAdminState Cisco Firepower sw:EthEstcEp:adminState managed object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricAdminState | .1.3.6.1.4.1.9.9.826.1.75.11.1.5 |
| cfprSwEthEstcEpAggrPortId Cisco Firepower sw:EthEstcEp:aggrPortId managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.6 |
| cfprSwEthEstcEpBorderAggrPortId Cisco Firepower sw:EthEstcEp:borderAggrPortId
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.7 |
| cfprSwEthEstcEpBorderPortId Cisco Firepower sw:EthEstcEp:borderPortId managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.8 |
| cfprSwEthEstcEpBorderSlotId Cisco Firepower sw:EthEstcEp:borderSlotId managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.75.11.1.9 |