mrNetMgmtModemDialDelay

CISCO-FASTHUB-MIB · .1.3.6.1.4.1.9.2.11.1.4.12

Object

scalar mandatory r/w Integer32
Specifies a delay in seconds between every dial-out failure.
The value zero indicates an infinite delay (no retry after
the first failure). Normally, FastHub will attempt a dial-out
if the mrNetMgmtModemDialString object is non-empty. If the
dial-out fails, and auto-answer has been disabled on this
system, the firmware will retry the dial-out after this delay
has passed. If auto-answer is enabled and the first dial-out
attempt fails, the system will immediately go into auto-answer
mode.
          
Default value: 300.

Context

MIB
CISCO-FASTHUB-MIB
OID
.1.3.6.1.4.1.9.2.11.1.4.12
Type
scalar
Access
readwrite
Status
mandatory
Parent
mrNetMgmt

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CISCO-FASTHUB-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FASTHUB-MIB::mrNetMgmtModemDialDelay.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-FASTHUB-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-FASTHUB-MIB::mrNetMgmtModemDialDelay'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-65500