cdot3OamErrFramePeriodThreshold

CISCO-DOT3-OAM-MIB · .1.3.6.1.4.1.9.10.136.1.5.1.7

Object

column r/w frames Unsigned32
The number of frame errors that must occur for this event to
be triggered.  The default value is one frame error.  If the
threshold value is zero, then an Event Notification OAMPDU is
sent periodically (at the end of every window).  This can be
used as an asynchronous notification to the peer OAM entity of
the statistics related to this threshold crossing alarm.
                              
If cdot3OamErrFramePeriodThreshold frame errors occur within a
window of cdot3OamErrFramePeriodWindow frames, an Event
Notification OAMPDU should be generated with an Errored Frame
Period Event TLV indicating the threshold has been crossed in
this window.

Context

MIB
CISCO-DOT3-OAM-MIB
OID
.1.3.6.1.4.1.9.10.136.1.5.1.7
Type
column
Access
readwrite
Status
current
Units
frames
Parent
cdot3OamEventConfigEntry

Syntax

frames Unsigned32

Values & Constraints