cDot11WidsEapolFloodStopTime
CISCO-DOT11-WIDS-MIB ·
.1.3.6.1.4.1.9.9.456.1.1.7.1.5
Object
This object indicates the time at which the
the EAPOL flood event observed first at the
time indicated by cDot11WidsEapolFloodStartTime
has stopped.
If this 802.11 station finds that the flood
conditions observed in the one or more prior
intervals has ceased, it marks the flood
event as stopped at the time indicated by
this object. That the flood has ceased is
indicated by the number of authentication
attempts dropping below the value specified by
the cDot11WidsEapolFloodThreshold object.
A value of 0 for this object indicates that
the number of authentication attempts continue
to exceed the value specified by the
cDot11WidsEapolFloodThreshold object.
Context
- MIB
- CISCO-DOT11-WIDS-MIB
- OID
.1.3.6.1.4.1.9.9.456.1.1.7.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cDot11WidsEapolFloodEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-DOT11-WIDS-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-DOT11-WIDS-MIB::cDot11WidsEapolFloodStopTime'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CISCO-DOT11-WIDS-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-DOT11-WIDS-MIB::cDot11WidsEapolFloodStopTime.<ifIndex>.<cDot11WidsEapolFloodIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-DOT11-WIDS-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-DOT11-WIDS-MIB::cDot11WidsEapolFloodStopTime'
Syntax
- Source
- SNMPv2-TCTimeStamp
- Base type
Unsigned32- Based on
- SNMPv2-SMITimeTicks
Type Description
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be
defined in the description of any object defined using this
type.
If sysUpTime is reset to zero as a result of a re-
initialization of the network management (sub)system, then
the values of all TimeStamp objects are also reset.
However, after approximately 497 days without a re-
initialization, the sysUpTime object will reach 2^^32-1 and
then increment around to zero; in this case, existing values
of TimeStamp objects do not change. This can lead to
ambiguities in the value of TimeStamp objects.
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of