cc6kxbarFlowCtrlBusFIFOThrMode

CISCO-CAT6K-CROSSBAR-MIB · .1.3.6.1.4.1.9.9.217.1.6.2

Object

scalar r/w Enumeration
Specifies the mode configuration of the system bus
flow control FIFO threshold.
          
off -- the flow control FIFO threshold is set to the
      original value defined by the system.
          
on -- the flow control FIFO threshold is set to the
      lower value defined by the system.
          
auto -- the system starts monitoring the system bus
      flow control FIFO threshold and will change the
      flow control FIFO threshold from the original
      value to the lower value when the system detects
      the first occurrence of the threshold exceeding
      on a physical entity (such as a module) over
      the system allowed limit.

Context

MIB
CISCO-CAT6K-CROSSBAR-MIB
OID
.1.3.6.1.4.1.9.9.217.1.6.2
Type
scalar
Access
readwrite
Status
current
Parent
cc6kxbarFlowCtrlObjects
Siblings
3

Syntax

Enumeration

Values & Constraints

Enumerated Values
1off
2on
3auto

Related Objects

Sibling Objects