rdwrConfSyncFullSyncMaxDelay
CDE-MIB ·
.1.3.6.1.4.1.89.35.1.161.2.14
Object
scalar r/w
Integer32
Maximum time in seconds between the need to full sync is detected and the actual full sync operation. Full sync will occure if this time passed, even if the master has been configured. range of 0 seconds to 1 hour. Default is 30 seconds.
Context
- MIB
- CDE-MIB
- OID
.1.3.6.1.4.1.89.35.1.161.2.14- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- rdwrConfigurationSyncConf
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CDE-MIB' -M '/opt/observium/mibs/radware:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CDE-MIB::rdwrConfSyncFullSyncMaxDelay.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CDE-MIB' -M '/opt/observium/mibs/radware:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CDE-MIB::rdwrConfSyncFullSyncMaxDelay'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-3600