tFTPStartSoftwareUpgrade
CAMBIUM-PTP600-MIB ·
.1.3.6.1.4.1.17713.6.9.8
Object
scalar
r/w
Integer32
Write '1' to this attribute to start the TFTP software upgrade process. The attribute will be reset to 0 when the upgrade process has finished. Continuing with the software upgrade will cause spectrum management (DSO) channel metrics collection to stop. The wireless unit will no longer search for the optimal operational radio channel. The performance of this wireless link may deterioate over time. If operating in a region where RADAR detection is mandatory you must complete the software upgrade and reboot the unit. Channel metrics collection will only be restarted after the wireless unit has been rebooted
Context
- MIB
- CAMBIUM-PTP600-MIB
- OID
.1.3.6.1.4.1.17713.6.9.8- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- management
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.