cadUpchannelFreqRange
CADANT-CMTS-UPCHANNEL-MIB ·
.1.3.6.1.4.1.4998.1.1.15.3.5.6
Object
scalar
r/w
Enumeration
This object is used to configure the C4 CMTS to accept upstream frequency ranges that conform with the EuroDOCSIS specifications (5 MHz to 65 MHz), to the extended range used in Japan (5 MHz to 55 MHz), or to the DOCSIS specifications (5 MHz to 42 MHz), or to the Arris extended range (5 MHz to 85 MHz). Changes to upstream frequency and width are verified against this object to ensure the C4 CMTS does not exceed the upstream spectrum limits imposed by this object. Attempting to narrow the upstream frequency spectrum implied by this object will fail if at least a single upstream is configured outside of the range for the new value. It is recommended this object be set during initial system setup.
Context
- MIB
- CADANT-CMTS-UPCHANNEL-MIB
- OID
.1.3.6.1.4.1.4998.1.1.15.3.5.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- cadUpchannelParams
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | none |
1 | european |
2 | japanese |
3 | northAmerican |
4 | extendedRange |