cadIfUpChannelFrequency

CADANT-CMTS-UPCHANNEL-MIB · .1.3.6.1.4.1.4998.1.1.15.3.2.1.4

Object

column r/w hertz Integer32
The center of the frequency band associated with this
upstream channel. This object returns 0 if the frequency
is undefined or unknown. Minimum permitted upstream
frequency is 5,000,000 Hz for current technology.  See
the associated conformance object for write conditions
and limitations.
              
The legal range may be restricted further, depending on 
the provisioned width of the channel.
For Docsis:
5.1-41.9 MHz for a 200 kHz channel
5.2-41.8 MHz for a 400 kHz channel
5.4-41.6 MHz for a 800 kHz channel
5.8-41.2 MHz for a 1600 kHz channel
6.6-40.4 MHz for a 3200 kHz channel
For Euro-Docsis:
5.1-64.9 MHz for a 200 kHz channel
5.2-64.8 MHz for a 400 kHz channel
5.4-64.6 MHz for a 800 kHz channel
5.8-64.2 MHz for a 1600 kHz channel
6.6-63.4 MHz for a 3200 kHz channel
              
Note that this entry will be read-only if 
cadIfUpChannelCloneGroupId is nonzero.