cadSpMgtTriggerThres2
CADANT-CMTS-SPECTRUM-MGMT-MIB ·
.1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.7
Object
column
r/w
0.001 percentage Unsigned32
This object is applicable for trigger type of degradation (3) and improvement (4). For degradation trigger, this is the maximum acceptable percentage of uncorrectable FEC errors. For improvement trigger, this is the minimum acceptable percentage of uncorrectable FEC errors.
Context
- MIB
- CADANT-CMTS-SPECTRUM-MGMT-MIB
- OID
.1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 0.001 percentage
- Parent
- cadSpMgtTriggerEntry
- Table
- cadSpMgtTriggerTable
- Siblings
- 8
Syntax
0.001 percentage Unsigned32
Values & Constraints
Object Constraints
range: 0-100000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cadSpMgtTriggerIndex The trigger index used to identify the trigger for each state
transition. | column | Integer32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.1 |
| cadSpMgtTriggerType The trigger type. | column | SpTriggerType | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.2 |
| cadSpMgtTriggerDay The trigger day is to specify the reoccurrence of the TOD
trigger for a week. The trigger day has the following defined
values:
0: Sunday
1: Monday
2: Tuesday
3: Wed… | column | SpTriggerDay | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.3 |
| cadSpMgtTriggerTOD Time of day to transition to next state, in HH:MM:SS format | column | SpTimeOfDay | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.4 |
| cadSpMgtTriggerPeriod The amount of time that should be loaded into a timer, in
seconds, once the state machine has transitioned into the
associated current state. When the timer expires, the transiti… | column | seconds Integer32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.5 |
| cadSpMgtTriggerThres1 This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the maximum acceptable
percentage of FEC errors (uncorrectable… | column | 0.001 percentage Unsigned32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.6 |
| cadSpMgtTriggerThres3 This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the minimum acceptable
Signal/Noise ratio (in dB).
For impr… | column | dB Integer32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.8 |
| cadSpMgtTriggerRowStatus The status of this conceptual row. To create a row in this
table, set this object to createAndGo(4). Support of the values
includes createAndGo(4) and destroy(6) | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.9 |