cadSpMgtTriggerRowStatus
CADANT-CMTS-SPECTRUM-MGMT-MIB ·
.1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.9
Object
The status of this conceptual row. To create a row in this table, set this object to createAndGo(4). Support of the values includes createAndGo(4) and destroy(6)
Context
- MIB
- CADANT-CMTS-SPECTRUM-MGMT-MIB
- OID
.1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cadSpMgtTriggerEntry
- Table
- cadSpMgtTriggerTable
- Siblings
- 8
Values & Constraints
Type Values
1 | active |
2 | notInService |
3 | notReady |
4 | createAndGo |
5 | createAndWait |
6 | destroy |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cadSpMgtTriggerIndex The trigger index used to identify the trigger for each state
transition. | column | Integer32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.1 |
| cadSpMgtTriggerType The trigger type. | column | SpTriggerType | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.2 |
| cadSpMgtTriggerDay The trigger day is to specify the reoccurrence of the TOD
trigger for a week. The trigger day has the following defined
values:
0: Sunday
1: Monday
2: Tuesday
3: Wed… | column | SpTriggerDay | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.3 |
| cadSpMgtTriggerTOD Time of day to transition to next state, in HH:MM:SS format | column | SpTimeOfDay | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.4 |
| cadSpMgtTriggerPeriod The amount of time that should be loaded into a timer, in
seconds, once the state machine has transitioned into the
associated current state. When the timer expires, the transiti… | column | seconds Integer32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.5 |
| cadSpMgtTriggerThres1 This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the maximum acceptable
percentage of FEC errors (uncorrectable… | column | 0.001 percentage Unsigned32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.6 |
| cadSpMgtTriggerThres2 This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the maximum acceptable
percentage of uncorrectable FEC error… | column | 0.001 percentage Unsigned32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.7 |
| cadSpMgtTriggerThres3 This object is applicable for trigger type of degradation (3)
and improvement (4).
For degradation trigger, this is the minimum acceptable
Signal/Noise ratio (in dB).
For impr… | column | dB Integer32 | .1.3.6.1.4.1.4998.1.1.15.4.2.1.3.1.8 |