cadSpMgtHistoryUFecError

CADANT-CMTS-SPECTRUM-MGMT-MIB · .1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.8

Object

column 0.001 percentageUnsigned32
This object is the measured percentage of uncorrectable
FEC errors for the upstream channel. This object is applicable 
	   when the value in cadSpMgtHistoryTriggerIndex defines the trigger 
	   of type degradation or improvement.

Context

MIB
CADANT-CMTS-SPECTRUM-MGMT-MIB
OID
.1.3.6.1.4.1.4998.1.1.15.4.2.1.5.1.8
Type
column
Access
readonly
Status
current
Units
0.001 percentage
Parent
cadSpMgtHistoryEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CADANT-CMTS-SPECTRUM-MGMT-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CADANT-CMTS-SPECTRUM-MGMT-MIB::cadSpMgtHistoryUFecError'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CADANT-CMTS-SPECTRUM-MGMT-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CADANT-CMTS-SPECTRUM-MGMT-MIB::cadSpMgtHistoryUFecError.<cadSpMgtHistoryUpChannelIfIndex>.<cadSpMgtHistoryTime>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CADANT-CMTS-SPECTRUM-MGMT-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CADANT-CMTS-SPECTRUM-MGMT-MIB::cadSpMgtHistoryUFecError'

Syntax

0.001 percentageUnsigned32

Values & Constraints

Object Constraints
range: 0-100000