cadPCAnomalyLastCleared

CADANT-CMTS-PACKETCABLE-MIB · .1.3.6.1.4.1.4998.1.1.115.1.1.46

Object

The value of sysUptime when the anomaly counts were last cleared.

Context

MIB
CADANT-CMTS-PACKETCABLE-MIB
OID
.1.3.6.1.4.1.4998.1.1.115.1.1.46
Type
scalar
Access
readonly
Status
current
Parent
cadPCMibBase

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CADANT-CMTS-PACKETCABLE-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CADANT-CMTS-PACKETCABLE-MIB::cadPCAnomalyLastCleared.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CADANT-CMTS-PACKETCABLE-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CADANT-CMTS-PACKETCABLE-MIB::cadPCAnomalyLastCleared'

Syntax

Source
SNMPv2-TCTimeStamp
Base type
Unsigned32
Based on
SNMPv2-SMITimeTicks
Type Description
The value of the sysUpTime object at which a specific
occurrence happened.  The specific occurrence must be
          
defined in the description of any object defined using this
type.
          
If sysUpTime is reset to zero as a result of a re-
initialization of the network management (sub)system, then
the values of all TimeStamp objects are also reset.
However, after approximately 497 days without a re-
initialization, the sysUpTime object will reach 2^^32-1 and
then increment around to zero; in this case, existing values
of TimeStamp objects do not change.  This can lead to
ambiguities in the value of TimeStamp objects.

Values & Constraints