cmUsCalTxPower
BRCM-CM-FACTORY-MIB ·
.1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4
Object
A set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibration parameters. cmUsCalModulation and cmUsCalFrequency will be used to determine the modulation scheme and transmit power that will be used.
Context
- MIB
- BRCM-CM-FACTORY-MIB
- OID
.1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- hundredth dBmV
- Parent
- cmFactoryUpstreamCalibration
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BRCM-CM-FACTORY-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-FACTORY-MIB::cmUsCalTxPower.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BRCM-CM-FACTORY-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BRCM-CM-FACTORY-MIB::cmUsCalTxPower'
Syntax
hundredth dBmVSNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647