cmDsCalLockNow
BRCM-CM-FACTORY-MIB ·
.1.3.6.1.4.1.4413.2.99.1.1.2.2.3.3
Object
When this object is set to true(1), the CM will attempt to lock to the downstream channel at a frequency specified by cmDsCalFrequency, and under the modulation type specified by cmDsCalModulation. Sets to false(2) will be accepted, but will not result in any action being taken. When read, this object always returns false(2).
Context
- MIB
- BRCM-CM-FACTORY-MIB
- OID
.1.3.6.1.4.1.4413.2.99.1.1.2.2.3.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- cmFactoryDownstreamCalibration
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BRCM-CM-FACTORY-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-FACTORY-MIB::cmDsCalLockNow.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BRCM-CM-FACTORY-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BRCM-CM-FACTORY-MIB::cmDsCalLockNow'
Syntax
- Source
- SNMPv2-TCTruthValue
- Base type
Enumeration
Type Description
Represents a boolean value.
Values & Constraints
Type Values
1 | true |
2 | false |