cmEmtaSafeReset

BRCM-CM-EMTA-MGMT-MIB · .1.3.6.1.4.1.4413.2.2.2.1.2.98.1.1.1.5

Object

scalar r/w SNMPv2-TCTruthValue
Setting this object to true(1) will cause the device to reset only 
when all telephony lines are on-hook.  If one or more lines are 
off-hook when the reset is invoked then the reset will be queued and 
will occur once all lines are on-hook.  Reading this object returns 
false(2) unless a reset is pending, in which case it returns true(1).  
A pending reset may be cancelled by setting this object to false(2).
          
Note that the behavior of this object is also affected by the values of
objects emtaPostCallCompletionResetDelay and emtaMaxResetDelay as 
described in the the BRCM-EMTA-MGMT-MIB.

Context

MIB
BRCM-CM-EMTA-MGMT-MIB
OID
.1.3.6.1.4.1.4413.2.2.2.1.2.98.1.1.1.5
Type
scalar
Access
readwrite
Status
current
Parent
cmEmtaBase

Syntax

SNMPv2-TCTruthValue

Values & Constraints

No enumerated values or constraints recorded.