bfdSessDesiredMinTxInterval

OBS ✓
BFD-STD-MIB · .1.3.6.1.2.1.222.1.2.1.25

Object

This object specifies the minimum interval, in
microseconds, that the local system would like to use
when transmitting BFD Control packets.  The value of
zero(0) is reserved in this case and should not be
used.
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in: Polling
Explore Observium network monitoring

Context

MIB
BFD-STD-MIB
OID
.1.3.6.1.2.1.222.1.2.1.25
Type
column
Access
readwrite
Status
current
Parent
bfdSessEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BFD-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BFD-STD-MIB::bfdSessDesiredMinTxInterval'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BFD-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BFD-STD-MIB::bfdSessDesiredMinTxInterval.<bfdSessIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BFD-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BFD-STD-MIB::bfdSessDesiredMinTxInterval'

Syntax

Values & Constraints

Type Constraints
range: 0..4294967295

Conformance

Member of
Compliance refinements
Write access is not required.