secLineModuleFWRev

BASIS-GENERIC-MIB · .1.3.6.1.4.1.351.110.2.1.31

Object

scalar mandatory OctetString
Firmware revision for Secondary line module
This object is applicable only to selected MGX switches.
If there is no Firmware revision, 
then this object returns 0.

Context

MIB
BASIS-GENERIC-MIB
OID
.1.3.6.1.4.1.351.110.2.1.31
Type
scalar
Access
readonly
Status
mandatory
Parent
cardInformation

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BASIS-GENERIC-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BASIS-GENERIC-MIB::secLineModuleFWRev.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BASIS-GENERIC-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BASIS-GENERIC-MIB::secLineModuleFWRev'

Syntax

OctetString

Values & Constraints

Object Constraints
range: 0-8