fsMplsL2VpnTrcFlag
Aricent-MPLS-MIB ·
.1.3.6.1.4.1.2076.13.1.5.1.1
Object
scalar
r/w
Integer32
This is a 4-byte (32-bit) object with each bit enabling/disabling a
particular type of trace/debug statement. Following is the convention
followed.
|<------------ 32 bits ------------>|
+--------+--------+--------+--------+
|00000000|00000000|00000000|00000000|
+--------+--------+--------+--------+
CPT VCCV Func Levels
GR
00000000 00000000 00000000 00000001 - Level One Critical Trace
00000000 00000000 00000000 00000011 - Level Two Error Trace that includes
level One
00000000 00000000 00000000 00000111 - Level Three Debug Trace that includes
level One and level Two
00000000 00000000 00000001 00000000 - Signalling Functional Traces
00000000 00000000 00000010 00000000 - Session Functional Traces
00000000 00000000 00000100 00000000 - VC Functional Traces
00000000 00000000 00001000 00000000 - Critical Functional Traces
01000000 00000000 00000000 00000000 - Debug Messages for Packet Rx
00100000 00000000 00000000 00000000 - Debug Messages for Packet Tx
01100000 00000000 00000000 00000000 - Debug Messages for Packet Tx and Rx
00000000 00000001 00000000 00000000 - VCCV critical debug statements
00000000 00000010 00000000 00000000 - VCCV management configuration
00000000 00000100 00000000 00000000 - VCCV capability exchange and selection
00000000 00001000 00000000 00000000 - Graceful Restart related debug Statements
Context
- MIB
- Aricent-MPLS-MIB
- OID
.1.3.6.1.4.1.2076.13.1.5.1.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fsMplsL2VpnConfigObjects
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.