currSoftSaveAs
AT-SETUP-MIB ·
.1.3.6.1.4.1.207.8.4.4.4.500.2.1.3
Object
Set with a filename to save the currently running software to
the root of flash. Only one save operation can be executed at a
time across all SNMP users, and the filename must not contain
whitespace characters.
Immediately upon executing the set action, the actual firmware
save operation will be started and continue on the device until
it has completed or a failure occurs.
Subsequent reads of the object will return one of several
results:
saving x A saving operation is currently in
progress. Another save cannot be started
while the object is returning this value.
x success The last save operation was successfully
completed.
x failure: [error] The last save operation failed, due to the
descriptive message attached. The most
common failure is lack of disk space.
idle There is no save operation in progress and
a new one may be started.
Upon reading a success or failure message, the message will be
cleared and the next read will result in an 'idle' message. A
new save operation can now be executed.
NOTE: This object has been replaced by objects currSoftSaveToFile,
currSoftSaveStatus and currSoftLastSaveResult.
Context
- MIB
- AT-SETUP-MIB
- OID
.1.3.6.1.4.1.207.8.4.4.4.500.2.1.3- Type
- scalar
- Access
- readwrite
- Status
- deprecated
- Parent
- currentFirmware
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'AT-SETUP-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AT-SETUP-MIB::currSoftSaveAs.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'AT-SETUP-MIB' -M '/opt/observium/mibs/allied:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'AT-SETUP-MIB::currSoftSaveAs'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Type Constraints
range: 0..255