fsRadExtDebugMask
ARICENT-RADIUS-EXT-MIB ·
.1.3.6.1.4.1.29601.2.30.1.1.1
Object
scalar
r/w
Integer32
This object is used to enable Trace Statements in
Radius Module.
A FOUR BYTE integer is used for enabling the level of tracing.
Each BIT in the four byte integer, represents a particular
level of Trace.
The maping between the bit positions & the level of trace is
as follows:
0 - Error Traces
1 - Event Traces
2 - Packet Traces
3 - Response Traces
4 - Timer Traces
5 - CoA Traces
The remaining bits are unused. Combination of levels are
also allowed.
For example if the bits 0 and 1 are set, then the Trace
statements related to Error and Event
will be printed.
The user has to enter the corresponding INTEGER VALUE for the
bits set. For example if bits 0 and 1 are set then user has to
give the value 3.
Context
- MIB
- ARICENT-RADIUS-EXT-MIB
- OID
.1.3.6.1.4.1.29601.2.30.1.1.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fsRadExtServer
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.