fsMstCistBridgeMaxAge
ARICENT-MST-MIB ·
.1.3.6.1.4.1.2076.80.1.13
Object
scalar
r/w
centi-seconds Integer32
The value that all bridges use for MaxAge when this bridge is acting as the root. The granularity of this timer is specified to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Context
- MIB
- ARICENT-MST-MIB
- OID
.1.3.6.1.4.1.2076.80.1.13- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- centi-seconds
- Parent
- dot1sFutureMst
Syntax
centi-seconds Integer32
Values & Constraints
Object Constraints
range: 600-4000