fsMplsTunnelSynchronizationStatus
ARICENT-MPLS-TE-MIB ·
.1.3.6.1.4.1.2076.13.12.1.2.1.18
Object
column
Integer32
Indicates the Synchronization status of the tunnel upon RSVP-TE Graceful
Restart. This object is applicable only for RSVP-TE signalled tunnels.
Following values are possible.
0. Not synchronized.
1. Downstream Synchronized.
2. Upstream Synchronized.
3. Fully Synchronized.
Fully Synchronized refers that the tunnel is fully recovered its state.
Both upstream and downstream nodes has helped the restarting node to recover its
state.
Downstream Synchronized refers that only downstream node has helped the
restarting node by sending RecoveryPath message. In this case, node saves the
RecoveryPath message and starts the recovery process after getting help from
upstream node also.
Upstream Synchronized refers that only uptream node has helped the
restarting node by sending Path message with recovery label object.
In this case, node saves the Path message and starts the recovery process
after getting help from downstream node also.
Not Synchronized state refers that both upstream node and downstream node has
not helped in recovering this tunnel.
Context
- MIB
- ARICENT-MPLS-TE-MIB
- OID
.1.3.6.1.4.1.2076.13.12.1.2.1.18- Type
- column
- Access
- readonly
- Status
- current
- Parent
- fsMplsTunnelEntry
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.