fsMplsRsvpTeReoptimizeTime

ARICENT-MPLS-RSVP-TE-MIB · .1.3.6.1.4.1.2076.13.2.2.35

Object

scalar r/w Integer32
This object is introduced in support of Reoptimization of LSP,
it is used to store the value of reoptimization time which is 
discussed in RFC 4736.
The default value is 60 seconds.
The acceptable range of values is 60 to 7200 seconds.

Context

MIB
ARICENT-MPLS-RSVP-TE-MIB
OID
.1.3.6.1.4.1.2076.13.2.2.35
Type
scalar
Access
readwrite
Status
current
Parent
fsMplsRsvpTeGenObjects

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.