fsMIIpDbTraceLevel
ARICENT-MIIPDB-MIB ·
.1.3.6.1.4.1.29601.2.48.1.5
Object
scalar
r/w
Integer32
This object is used to enable trace statements in IP binding
database module.
A four byte integer is used for enabling the trace level.
Each bit in the four byte integer represents a particular
trace level.
The mapping between the bit positions & the trace level is
as follows:
BIT 1 - Function entry traces
BIT 2 - Function Exit traces
BIT 3 - Debug traces
BIT 4 - Failure traces
BIT 5 - Function arguments trace
The remaining bits are unused. Combination of levels are
also allowed.
For example if the bits 1 and 2 are set, then the trace
statement related to function entry and exit will be printed.
The user has to enter the corresponding integer value for the
bits set. For example if bits 1 and 2 are to be set ,then user
has to give the value 6.
Context
- MIB
- ARICENT-MIIPDB-MIB
- OID
.1.3.6.1.4.1.29601.2.48.1.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fsMIIpDbScalars
Syntax
Integer32
Values & Constraints