fsErpsRingConfigHoldOffTime
ARICENT-ERPS-MIB ·
.1.3.6.1.4.1.29601.2.40.2.3.1.1
Object
column
r/w
milliseconds Unsigned32
This object is used to configure the period for the hold-off timer
of this ring.
Hold-Off timer will be started when a new defect (SF) is received for
this ring. This defect will not be given as local SF to ERP control
process until Hold-Off timer expires.
When the Hold-Off timer expires and if a local defect still exists, it
will be given as local SF to the ERPS control process of this ring.
The configured value of this timer is applicable only from the next
start/re-start of the timer.
The Hold-Off timer has a period from 0 to 1 hour, configurable in units
of 1 milliseconds. For example, to configure Hold-Off Time as 5 seconds,
configure the value as 5000. Default value of Hold-Off timer is 0
Context
- MIB
- ARICENT-ERPS-MIB
- OID
.1.3.6.1.4.1.29601.2.40.2.3.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- fsErpsRingConfigEntry
Syntax
milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 0-3600000