fsErpsRingConfigGuardTime
ARICENT-ERPS-MIB ·
.1.3.6.1.4.1.29601.2.40.2.3.1.2
Object
column
r/w
milliseconds Unsigned32
This object is used to configure the period for the guard timer of this
ring. This timer is required to prevent reception of outdated R-APS
messages.
Guard timer will be started on reception of local clear SF event.
R-APS messages (except R-APS event messages) received during the running
of the guard timer will be discarded.
The configured value of this timer is applicable only from the next
start/re-start of the timer.
The guard timer has a period from 0 to 1 hour, configurable in units of
1 millisecond. For example, to configure GuardTime as 1 second,
configure the value as 1000.
Context
- MIB
- ARICENT-ERPS-MIB
- OID
.1.3.6.1.4.1.29601.2.40.2.3.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- fsErpsRingConfigEntry
Syntax
milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 0-3600000