fsEcfmTraceOption
ARICENT-ECFM-MIB ·
.1.3.6.1.4.1.2076.150.1.4
Object
scalar
r/w
Integer32
This object is used to enable trace statements in
Ethernet CFM module.
A four byte integer is used for enabling the trace level.
Each bit in the four byte integer represents a particular
trace level.
The mapping between the bit positions & the trace level is
as follows:
Bit 0 - Init and Shutdown traces
Bit 1 - Management traces
Bit 2 - Data Path traces [NOT REQUIRED IN ECFM]
Bit 3 - Control Plane traces
Bit 4 - Packet Dump traces
Bit 5 - Traces related to all resources except buffers
Bit 6 - All Failure traces
Bit 7 - Buffer allocation/release traces
Bit 16 - ECFM Function Entry traces
Bit 17 - ECFM Function Exit traces
Bit 18 - ECFM Name traces
The remaining bits are unused. Combinations of levels are
also allowed.
For example, if the bits 19 and 20 are set, then the trace
statement related to discovery and remote loopback related
messages will be printed.
The user has to enter the corresponding integer value for the
bits set. For example if bits 8 and 9 are to be set ,then user
has to give the value 0x300.
Context
- MIB
- ARICENT-ECFM-MIB
- OID
.1.3.6.1.4.1.2076.150.1.4- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fsEcfmSystem
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.