junidApsConfigMode
APS-MIB-JUNI ·
.1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.3
Object
column
r/w
Enumeration
The architecture of the APS group.
onePlusOne
The 1+1 architecture permanently bridges the working
line to the protection line.
oneToN
The 1:n architecture allows one protection channel to
protect up to n working channels. When a fault is detected
on one of the n working channels that channel is bridged
over the protection channel.
onePlusOneCompatible
This refers to 1 + 1 bidirectional switching compatible with
1:n bidirectional switching as specified in ITU-T
Recommendation G.783 (04/97) section A.3.4.1. Since this
mode necessitates bidirectional switching, junidApsConfigDirection
must be set to bidirectional whenever onePlusOneCompatible is set.
onePlusOneOptimized
This refers to 1 + 1 bidirectional switching optimized
for a network using predominantly 1 + 1 bidirectional
switching as specified in ITU-T Recommendation G.783 (04/97)
section B.1. Since this mode necessitates bidirectional
switching, junidApsConfigDirection must be set to bidirectional
whenever onePlusOneOptimized is set.
This object may not be modified if the associated
junidApsConfigRowStatus object is equal to active(1).
Context
- MIB
- APS-MIB-JUNI
- OID
.1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- junidApsConfigEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | onePlusOne |
2 | oneToN |
3 | onePlusOneCompatible |
4 | onePlusOneOptimized |